Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Chinese Journal of Radiological Medicine and Protection ; (12): 951-955, 2021.
Article in Chinese | WPRIM | ID: wpr-910423

ABSTRACT

Objective:To determine the peak skin dose (PSD) to patients from neuro-interventional procedures and evaluate the risk of the deterministic effect.Methods:Gafchromic XR RV3 films were used in a level A tertiary hospital in Beijing to measure the patients′ PSD from neuro-interventional procedures, mainly three common types of procedures, including vascular embolization, vascular angioplasty and vascular angiography. The films were scanned by Epson Expression 10000XL, read by ImageJ software, and analyzed by Film QA Pro?2014 software.Results:PSD was measured in 23 embolizations, 14 stentings and 12 arteriography. There were 20 patients whose PSD were equal or greater than 2 Gy, including 15 in vascular embolization and 5 in angioplasty. The PSDs to patients in cerebral arteriography were all below 2 Gy. The PSDs to some of the patients were higher than the threshold for deterministic effect recommended by ICRP Publication 118.Conclusions:There is a risk of deterministic effect in neurointerventional procedures. It is suggested that the patients be followed up to observe their radiation injury as well as to know in time the subsequent diagnosis and treatment.

SELECTION OF CITATIONS
SEARCH DETAIL